Standards for placing a boiler room in a private house

Requirements for the room for installing a gas boiler - SNiP, diagram, tips

Requirements for boiler rooms in public buildings

The premises in which the gas boiler will operate are stipulated in SNiP 31-02-2001, DBN V.2.5-20-2001, SNiP II-35-76, SNiP 42-01-2002 and SP 41-104-2000 - these documents exclude or minimize any emergencies.

Premises for placing gas boilers fall under the classification of fire and explosives, therefore, when designing, planning, installing and setting up gas heating equipment, all requirements for a room for installing a gas boiler must be strictly observed.

General requirements for the installation of gas appliances

In the room intended for the installation of a gas boiler, according to the above standards, there must be good natural lighting: at least 0.03 m2 of the window opening area must fall on 1 m3 (but not windows - partitions, frames and imposts are not taken into account). It is imperative to equip the room with a supply and exhaust ventilation system according to the following rules: the total volume of forward and reverse air flows per hour, multiplied by 3, is equal to the volume of the entire exhaust device. In addition to a window equipped with a window, a door with access to the street is installed in the room. The table shows the requirements for the volume of the room:

Gas boiler powerThe total volume of the furnace
7.5 m3
> 30-60 kW13.5 m3
> 60-200 kWRequirements according to the conditions of installation and operation of the boiler on gas, but not less than 15 m3

For gas-fired units with a power of more than 6000 W, add 0.2 m3 for each extra unit of power.

Supervisory requirements for the room for the installation of a gas boiler stipulate that it is allowed to operate any appliances for heating an apartment on every floor of a multi-storey building and in any room of an apartment.

Kitchens in multi-storey buildings are also suitable for these requirements, since they are already equipped with appropriate communications.

The only condition is that the total thermal power of all devices for heating water and heating an apartment (boilers, boilers, heating elements, heating radiators, batteries or registers) should not exceed 150 kW in total.

Indoor ceiling heights - 2 meters or more. The room in which the gas boiler will be installed and operated must be separated from the neighboring rooms by capital fireproof walls.

Material for walls or partitions should have a time limit of fire resistance of 0.75 hours (45 minutes).

The boiler room must be planned so that in the event of a fire in operation, there is no possibility for the fire to spread throughout the apartment.

Gas boilers of the TLO brand, operating on the principle of natural circulation of the coolant, can be installed and should be operated only in the basement of the house or in the basement rooms.

  1. The ceiling is 2 meters or more.
  2. The total volume of the kitchen is more than 7.5 m3, ventilation is equipped, a window is installed and there is a door opening onto a balcony.
  3. For air exchange, it is necessary to equip a grate at the bottom of a wall or door that goes into the next room, the area of ​​the grate is at least 0.02 m2.

To install a gas boiler in the kitchen, a permit from the gas service may be required.

Tips & Tricks

The experience of operating Russian and foreign heating equipment makes it possible to formulate a number of tips and recommendations, taking into account which will help to avoid additional costs and ensure a comfortable standard of living:

  • Installing a voltage stabilizer will protect the electronic boards or the boiler automation from failure due to power surges. Such boards cannot be repaired, and the replacement cost can reach 30% of the price of the entire boiler.
  • Sewer drain with a drain in the boiler room floor will help to avoid flooding in the event of a coolant leak or an accident in the water supply circuit
  • Installation of a boiler room in a private house with the installation of a heating control system for outside or room temperature brings significant savings in the form of reduced fuel costs. The amount of such savings in a time span of two to three years exceeds the cost of additional costs for the installation of such automation.
  • When using antifreeze, remember that not all boiler manufacturers allow it to be used in their products. Using it in boilers of such manufacturers may result in loss of warranty.
  • Aluminum and copper make up a galvanic pair with each other, which leads to accelerated corrosion of the compounds of these metals. For this reason, contact of aluminum radiators in the boiler room with a copper pipe of the heating circuit should be excluded.
  • In the absence of automatic temperature control in individual rooms, it is advisable to install adjustable valves with thermostatic heads on the radiators. This solution automatically maintains the set temperature.
  • An important role in the layout of equipment is played by the requirement for its maintainability. Easy and convenient access to all elements when urgent repairs or replacement of equipment in a boiler room in a private house is needed - a guarantee of quick and easy troubleshooting and accidents

Read other articles on this topic

Modular gas boiler roomGas boiler room in a private house
Electric boilers for heating a private house: features, how to choose, applicationWood-fired boiler for home heating - DIY installation
Combined heating boilers: types, featuresStand-alone boiler room for a private house
How to choose a gas boiler for heating a private houseBoiler room design standards in a private house
How to choose a boiler for home heatingDiesel heating boilers

Services on this subject

Installation of a boiler room in a private houseBoiler room design
Turnkey installation of boiler roomsInstallation of a gas heating boiler
Installation of gas boiler housesInstallation of home heating boilers
Installation of an electric heating boilerInstallation of a solid fuel boiler
Pellet boiler installationInstallation of a diesel boiler
Installation of wall-mounted gas boilersInstalling a gas boiler in a private house
The cost of installing gas boilersInstallation of floor-standing gas boilers

Requirements for boiler rooms in public buildings

Requirements for boiler rooms in public buildings

1.8. * For public buildings, it is allowed to design built-in boiler rooms when using: - hot water boilers with a water heating temperature of up to 115 ° C.

- steam boilers with saturated steam pressure up to 0.07 MPa, satisfying the condition (t - 100) * V ≤ 100 for each boiler, where t is the saturated steam temperature at the design pressure, ° C; V - boiler water volume, m3; The total thermal power of an individual boiler house should not exceed the heat demand of the building or structure for which it is intended for heat supply, in addition, the thermal power should not exceed: 3.0 MW - for a roof boiler house and for an integrated boiler house with boilers for liquid and gaseous fuels;

1.5 MW - for a built-in boiler room with solid fuel boilers

It is not allowed to design built-in boiler rooms for buildings of preschool and school institutions, for medical and dormitory buildings of hospitals, clinics, sanatoriums and recreation facilities.

1.10.

It is not allowed to place built-in boiler rooms under public premises (foyers and auditoriums, commercial premises of shops, classrooms and auditoriums of educational institutions, halls of canteens, restaurants, dressing rooms and soap baths, showers, etc.) and under warehouses of combustible materials.

1.18. * The projects of boiler rooms should provide for: For built-in boiler rooms, automated boilers of full factory readiness should be provided.

1.23. * Built-in boiler rooms should be separated from adjacent premises by type 2 fire walls or type 1 fire partitions and type 3 fire ceilings.

Attached boiler rooms must be separated from the main building by a type 2 fire wall.

In this case, the wall of the building, to which the boiler room is attached, must have a fire resistance limit of at least 0.75 hours, and the overlap of the boiler room must be made of non-combustible materials.

3.10. * Exits from built-in boiler rooms should be provided directly to the outside.

Marches of stairs for built-in boiler rooms are allowed to be located in the dimensions of common staircases, separating these marches from the rest of the staircase with fireproof partitions and ceilings with a fire resistance limit of at least 0.75 hours.

7.14. * The height of the mouth of the chimneys for built-in boiler rooms must be above the boundary of the wind support, but not less than 0.5 m above the roof, and also at least 2 m above the roof of the higher part of the building or the tallest building within a radius of 10 m.

For obvious reasons, I cannot answer specifically. When designing an object for which there are no design standards, it will be necessary to develop STU - special technical conditions.

Dmitry Gorokhov

02/06/2018 at 6:27 pm | #

I have a three storey store. A second fire exit was made from each floor. The exit area of ​​the first floor passes directly under the boiler room (otherwise it does not work), Question - is this a violation?

Without seeing the layout, it is difficult to imagine the architecture of the building. Intuition suggests that the violation should be sought in the placement of the boiler room on the second floor.

6.9. Requirements for boiler house buildings

6.9.1 The requirements of this subsection should be observed when designing buildings and structures for boiler houses.

When designing built-in, attached and roof boiler rooms, one should additionally be guided by the requirements of building codes and regulations of those buildings and structures for which they are intended to supply heat.

6.9.2 Stand-alone boiler house buildings in terms of fire resistance, class of constructive fire hazard, building height and floor area within the fire compartment are accepted in accordance with the requirements for industrial buildings.

Buildings of detached, attached and built-in boiler rooms are made of I and II degree of fire resistance of fire hazard class C0; III degree of fire resistance of fire hazard classes C0 and C1.

Buildings of stand-alone boiler houses, belonging to the second category in terms of the reliability of heat supply to consumers, can also be performed with IV degree of fire resistance of fire hazard class C0, C1.

Roof boiler house structures must have a fire resistance degree of at least III and belong to the C0 fire hazard class.

6.9.3 Roof boiler rooms are single-storey. The roof covering of the building under the roof boiler room and at a distance of 2 m from its walls must be made of NG materials or protected from fire by a concrete screed with a thickness of at least 20 mm.

6.9.4 When blocking a boiler room with a closed storage of solid fuel, the latter must be separated by a type 1 fire wall with a fire resistance rating of at least REI 150.

6.9.5 Attached boiler rooms should be separated from the main building by a type 2 fire wall.

The overlap of the boiler room should be made of NG materials.

6.9.6 Built-in and roof boiler rooms should be separated from adjacent rooms and the attic by type 2 fire walls or type 1 fire walls, type 3 fire ceilings.

It is not allowed to place built-in boiler rooms under living quarters, directly on the ceilings of living quarters adjacent to living quarters, as well as above and below rooms of categories A and B.

6.9.7 The premises of the service personnel built into the building of the boiler room are separated from the production premises by fire-prevention partitions of the 1st type and fire-prevention ceilings of the 3rd type.

6.9.8 The above-bunker fuel supply galleries must be separated from the boiler rooms by partitions (without openings) of the 2nd type. It is allowed, as an exception, to arrange a doorway in the specified partition as an escape exit through the boiler room.

In this case, the communication between the above-bunker gallery and the boiler room must be carried out through the vestibule. The fire resistance limit of the vestibule enclosing structures must be at least REI 45, and the fire resistance limit of doors in the partition and the vestibule must be at least EI 30.

6.9.9 In boiler rooms (but not above boilers or economizers) of detached boiler rooms, it is allowed to provide for the installation of closed liquid fuel supply tanks with a capacity of no more than 5 m3? for fuel oil and 1 m3? for light fuel oil.

6.9.10 For built-in and attached boiler rooms, the total capacity of the supply tanks installed in the boiler room should not exceed 0.8 m3.

Source: https://yokvadro.ru/stati/trebovanija-k-kotelnym-obshhestvennyh.html

Requirements for solid fuel boilers

boiler room with solid fuel boilers

  1. The required distance from the wall to the boiler is about 10-12 centimeters;
  2. If a solid fuel boiler is installed in a wooden room, then in advance it is necessary to trim the wall adjacent to the boiler with sheets of steel;
  3. It is advisable to make the floor in the room of concrete;
  4. There must be a window and vents;
  5. The room must be at least 8-10 square meters.

Before installing the boiler in your private house or cottage, you need to choose the right unit itself. There are a lot of them on the market, boilers of domestic manufacturers and foreign firms are abundant. The requirements for the boiler room where the boiler will be installed depends on the power of the purchased device.

It should be noted that the room requirements for the installation of different types of boilers are almost the same. There are small differences and these differences are fateful. Not all consumers and craftsmen know these nuances. And it often happens that the specialists have installed the boiler and it is ready for work, but, for example, the gas service does not sign the boiler operation certificate, because all the requirements have not been met. The room needs to be redone urgently. Therefore, it is very important to comply with the standards for the boiler room!

Standards and requirements for a boiler room in a private house

Requirements for boiler rooms in public buildings

Currently, there is a steady demand for suburban real estate in the immediate suburbs of large and small cities.

Modern technologies in construction make it possible to fulfill an old dream of many people, to live in nature in their home.

The device of a modern heating system is the main question facing the developer.

Large selection of heating systems. A wide range of boiler equipment and automation, ensuring stable and safe work in a residential building.

It is better to build a boiler room in a private house for masters of their craft. During construction, it is necessary to know the basic norms and requirements for a boiler room in a private house.

It is forbidden to build a room for a boiler anywhere and anyway.

Types of heating boilers

Fire and gas services have certain requirements for a boiler room in a private house. Guided by the rules and regulations, first of all, it is necessary to decide which boilers will heat the cottage.

  • Solid fuel boiler.
  • Liquid fuel boiler.
  • Gas boiler.
  • Combined boiler (Boilers of these types operate on solid fuel, liquid fuel, gas).
  • Electric boiler.

Places of installation of heating boilers

  • Autonomously built boiler houses (Boiler houses built separately from a residential building)
  • Roof boiler rooms (Boiler rooms located on the roof of the house)
  • Modular boiler rooms (Boiler rooms placed in containers or block modules)
  • Built-in boiler rooms. (Boiler rooms located inside a residential building)
  • Attached boiler rooms (Boiler rooms attached close to the cottage)

A large range of heating boilers can be confusing for the developer. For the optimal decision on which boiler to buy, professional advice is needed. If there is no cottage project with all the calculations, where and how everything should be located, then the knowledge of experienced installers will help to avoid mistakes, determining what is the minimum boiler room area in your house.

Gas fired boiler houses

Requirements for gas boilers. Connection of the private sector to the natural gas network without approval and a completed project is not allowed:

  1. One of the requirements is the entrance to the boiler room. The doors to the boiler room must open to the outside.
  2. The dimensions of the boiler room must be built taking into account the boiler capacity. The volume of the boiler room for a private house is required to make a three-fold air exchange. A simple calculation of ventilation is 3 cubic meters per second per square meter.
  3. To ensure the regulatory requirements, the ventilation in the boiler room of a private house must be three times air exchange. Construction standards, adhered to the SNIP calculation of boiler room ventilation and the size of windows and doors, will ensure the safe operation of the boiler in the house.
  4. The minimum window size in the boiler room should be 0.5 m2. The norm for calculating windows in the boiler room is as follows: 0.03 square meters per 1 cubic meter of volume.
  5. The window in the boiler room building must have a window. The window openings in the boiler room work like an explosive valve. In the event of an explosion, due to the increased concentration of gas in the room, windows fly out. The walls remain intact.

The boiler room must be completed

  1. The walls are brick, concrete or non-combustible.
  2. The floors are concreted and tiled.
  3. Door width at least 80 cm.
  4. Fire door.
  5. Installation of 2 boilers is allowed.
  6. Maximum natural light.
  7. Boiler room ventilation.

Boilers up to 30 kW are allowed to be installed in the kitchen.

Minimum kitchen size:

  1. Area 7.5 m2.
  2. The ceiling is 2.5 meters.
  3. Volume 15 m3.

Preference is given to separately erected boiler houses. One of the conditions for the construction of a boiler house is a separately erected foundation. If the boiler is floor-standing, then a separate foundation and a podium are erected under the boiler.

The chimney, if the boiler equipment is of a non-coaxial type, is erected on a specially built foundation under it. The chimney is equipped with a tee for cleaning it. The gas boiler must be serviced at least once a year.

A separate gas boiler room is being installed in the form of a mini-boiler room. You can build such a boiler room with your own hands. A container can be used for placing under the boiler room. Such a boiler room will not take up space in the house. She's safe. There is no small noise from the boiler.

Isoproflex pipes, buried only 60 cm in the ground and excluding heat losses, are perfect for heating mains from the boiler room to the cottage.

Solid fuel boiler houses

The requirements for boiler houses equipped with solid fuel boilers are not as stringent as for gas ones. The range of solid fuel boilers is very wide. The only thing that unites all models of boilers of this type is that they are all floor standing.

Particular attention is paid to the foundation for the boiler and chimney. The approach to the disposal of combustion products is special. The chimney is made with a hole in the lower part to remove combustion products:

  1. 8 cm2 per 1 kW of boiler power.
  2. 24 cm2 per 1 kW of boiler output (boiler in the basement).

Installation of the boiler on a concrete base. The construction of the podium is desirable. A sheet of metal is laid on the floor in front of the boiler.

Fire extinguishing means must comply with the SNiP of fire safety. The size of the boiler room for solid fuel boilers must be at least 8 m2.

Supply ventilation in a boiler room with a solid fuel boiler must ensure air exchange in three times. Correctly selected and constructed volume of the boiler room will ensure the safe operation of boiler equipment and the cottage as a whole.

An example of a boiler room with an interesting solution

There is an interesting solution for the construction of a coal-fired boiler house. The boiler house building is being erected right along the border of the site. The boiler room is two-level. Boiler room at an elevation of -2.5 m. The total area is divided into 2 rooms.

In the first, the boiler is directly installed. The second room is equipped for fuel storage. In our case, coal. Both rooms are equipped with a ventilation system corresponding to SNiP. Natural lighting through the windows. The window must have vents.

The fuel storage room is arranged as follows.

A bunker made of sheet steel has been assembled. The hopper is loaded thanks to an inclined chute welded from sheet steel, which leads directly to the hopper. A truck with coal is unloaded from the street side by the wall of the boiler room. In an open chute in the wall, the coal flows directly into the hopper.

The physical costs of storing the required volume of coal are minimized. A boiler located at the minus mark performs better. There is no need to install a circulation pump.

The room on the first floor of the boiler room can be used for any auxiliary rooms. It is very good to place such a boiler room on the corner of your site, if there is one.

Oil fired boilers

It is preferable to build a boiler room for liquid fuel boilers separately from the cottage. The construction of a boiler module, standing apart from a residential building, is due to the following considerations:

  1. No diesel smell.
  2. Fire safety.
  3. Convenient fuel injection into fuel tanks.
  4. Fire — an insulated fuel house separated by a brick wall from the boiler room.

Tanks for diesel fuel in the built-in boiler room can also be placed inside the house. The storage room for diesel fuel should be about 2.5 meters high. The containers take up a lot of space in the cottage.

It is necessary to take into account the dimensions of the fuel tanks during the construction of the boiler house and the methods of refueling them with diesel fuel.

Requirements for a boiler room with an electric boiler

An electric boiler is the safest of all types of boilers. The liquid is heated by electricity. There is no carbon monoxide from it. The electric boiler does not need ventilation. It is not difficult to make a room for a boiler room with your own hands. Here is a list of requirements:

  1. Make grounding. At home, it is enough to drive three steel corners into the ground 1.5 meters on the street. Connect them together. Checking the quality of grounding is as follows. It is necessary to take the phase from the electrical outlet, zero from ground. If everything is done correctly, then any electrical appliance should work. That is, turn on.
  2. Installation of machines that cut off electricity.
  3. Laying a separate cable for connecting an electric boiler.
  4. Dry room for an electric boiler.
  5. The premises must be sufficient for connecting heating and water supply pipelines to an electric boiler.
  6. Natural light is preferable with a window area of ​​0.5 m2.
  7. 12 kW boilers consume three-phase power supply.

Completion

All the above recommendations will help you avoid mistakes when choosing a room for a boiler room in a private house.

A boiler room in a wooden house is no exception.

When designing your cottage, you need to decide on the home heating system.The type and model of boiler equipment, its mode of operation.

In order to avoid gross mistakes, it is advisable to order a project from professionals. The construction of a boiler room in a private house is a serious business and requires special attention.

Source: https://NormaTeh.ru/teplosnabzhenie/trebovaniya-k-pomeshcheniyu-kotelnoj-dome.html

Boiler room ventilation system

In order for the heating device to function as efficiently as possible (and the principle of its operation, we remind you once again, is based on the combustion of gas and the resulting heat release), it is necessary that fresh air constantly flows into the room, which is extremely necessary to remove the products of fuel combustion. In most cases, in order for the air exchange in the boiler room to reach the required level, ordinary natural ventilation is sufficient. Dilapidated doors and window frames, as well as a number of other places where, for one reason or another, there are cracks, provide an ample amount of fresh air. But if all this is not enough, since the room is sealed, then it is advisable to take a closer look at the possibility of equipping an additional ventilation system. And if this is not done, then the combustion products will remain inside the room, leaving traces in the form of soot and soot on all surfaces. Moreover, the unattractive appearance of the furnace is only the smallest problem that will befall you in the absence of proper ventilation.

requirements for the ventilation system in the boiler room

Natural ventilation

If the power of the heater does not exceed 30 kilowatts, then for the installation of natural ventilation, you simply need to drill holes of 10-15 centimeters in the walls and install a plastic pipe of the appropriate size in it - this is how we will make a kind of air duct. There is only one little thing left: to protect this channel from the penetration of insects and debris entering it. To do this, we can use a regular mesh made of iron or plastic. In addition, the inner part of the duct must be provided with a reverse flow valve, which is necessary for the air to escape from the room. In the same way, it is necessary to equip a ventilation hood, moreover, it should be protected from atmospheric precipitation when leaving.

But where is the best place to place the inlet? What do the requirements for a boiler room in a private house tell us about this? They say the following: such a hole should be located next to the firebox, below. In this case, fresh air will flow directly into the combustion chamber, but not soar throughout the entire combustion room. It is better to equip the hood immediately above the device, because the combustion products, as you know, will rise up.

Artificial ventilation

Not in all cases it is possible to equip natural ventilation. After all, it largely depends on weather conditions, and you will not be able to control its work in any way. Then it is better to resort to another of its types - artificial ventilation.

Important! The main elements of such a design are fans, they should be selected based on the maximum consumption of air the boiler needs, adding another 30 percent to this.

Actually, we have everything in terms of ventilation.

Boilers

Ovens